Sign In | Join Free | My polstate.com |
|
Model NO. : PG-700
Gluing Mode : Auto Feeding
Packaging Material : Ab Compound Material
Glue Type : Epoxy , Silicone ,PU
Application : Medical
Driven Type : Mechanical
Packaging : Polywood Case
Xyz Working Area : 700 X 700 X 100mm
Size : L1500xw1200xh1500mm
Weight : 260kg
Ratio : From 1:1 to 10:1
Stiring Method : Static or Dynamic
Pump : Daheng Patent Plunger Pump
out-Gluing Rate : 5-66g/5s
Mixing Precision : +/-1%
Container Volume : a:25L B:10L
Transport Package : Carton Box Lined with Foaming PC
Specification : CE
Trademark : Daheng or OEM
Origin : Guangzhou China
HS Code : 8424899990
Supply Ability : 50PCS / Month
Package Size : 100.00cm * 100.00cm * 100.00cm
Package Gross Weight : 100.000kg
After-sales Service : 1 Year
Warranty : 1 Year
Automatic Grade : Automatic
Customization : Available | Customized Request
Shipping Cost : about shipping cost and estimated delivery time.
: Initial Payment Full Payment
Currency : US$
Return&refunds : You can apply for a refund up to 30 days after receipt of the products.
ITEM | Parameter |
Mixing ratio | 1:1--10:1 adjustable |
Working range | 700*700*100mm |
Displacement speed | 250mm/s(speed) |
Out-glue speed | 1-12g/s per single pump |
Accuracy | ±2%(output volume)±2%(mixing) |
tolerance | ≤0.2mm |
Flow control | Digital input |
Program memory | 99pcs-999pcs |
Motion trail | Dot , line ,curve ,circle |
Automatic controlling system | Touch screen (to achieve program programming, modification, storage and so on |
Out-glue control system | AB glue back suction valve, achieve AB glue independent operation |
Programmatically | Tech programming/or computer systems (Micro software Windows 7,Windows10 optional) |
Mixing method | dynamic mixing |
Power supply | 220V/50Hz/1500W without heating |
Air source | 0.5-0.8Mpa |
Viscosity range | 50-20000cps |
Outer dimension | 1500L*1200W*1600H mm |
A tank | 10L 25L 40L stainless tank(optional) |
B tank | 10L 25L 40L stainless tank(optional) |
Others | AB tank ,A pump,AB pipeline heating function |
Drops always happened when valve closed . The reason may be low concentration of glue , big air-pressure or large diameter of needles.
Narrow needles will effect the flow of the liquid and cause back pressure . It will lead to dropping when the valve closed . Too narrow needles will effect the drainage of air when valve start to work, but it can be solved if change suitable needles .
Conical needles with less back pressure and liquid flow smoothly .
It is better to drainage of the air advance or use no-foam glue or deaeration to avoid the air cause dropping after valve closed .
The problem cause mainly because of the storage flow pressure tank or air pressure is not stable.
Inlet pressure regulating table should be set lower 10-15psi than factory minimum pressure . The pressure in pressure tank should be set upper than the middle pressure of regulating table . It should be avoided to use the pressure lower than the middle pressure of regulating table .
Control pressure of rubber valve at least higher than 60psi to assured glue evenly .
We should check the glue output speed at last . The glue is uneven if the time less than 15/1000s , the output speed more longer , the glue dispensing will be more stable .
It should be changed the pipe from 1/4 to 3/8 if the flow velocity too slowly .
The pipe is the shorter the better if no requirement .
Excessive fluid pressure and short valve opening time may lead to the air infiltration liquid . We can use the conical needles and reduce fluid pressure .
This problem is caused by heavy moisture and recycle instant glue . We should make sure to use new instant glue and wash the pipes with dry . Make sure air dry and add filter between plant air pressure and valve .
Make sure to use black pipeline.
Don't add new UV glue to old UV glue in pressure tank , we should drain off the old UV glue before pouring new UV glue into pressure tank because the UV glue will produce bubble after a period of time and lead to glue dispensing unevenly .
Normally , it may cause air problem if the needle less than NO.20 . It is better to use large steel needles or conical needles to avoid to use winding needles needles
It is better to use storage pressure cylinder of methybenzene toluene to self-cleaning one time for each shift . The more frequently cleaning the better .
![]() |